INSTALLATION
4.
Connect the cable to a protection device at the System 25 location.
5. Connect the second protection device to an 858A Adapter on the617A
Panel, using 4-pair inside wiring cable.
6. Connect the 858A Adapter to a port on a TN742 circuit pack using an
octopus cable.
Out-of-Building Voice Terminals (ZTN79)
Transmission facilities (voice pairs) that extend out-of-building and are not
included in the interface may be installed by the telephone company or through
other means (e.g., the building and/or property owner). These facilities, aerial or
buried, must be protected with voltage limiting devices and sneak current fuses.
The only exception to this rule is buried cable that is enclosed in a continuous
metallic conduit from one building entrance to the other. In this case, the conduit
must be connected to an approved building ground at each end.
If single-line terminals are extended out-of-building, standard protection devices
fcr voice pairs should be used. If 7300 H-type voice terminals are extended out-
of-building, the facilities must be protected with an In-Range Out-Of-Building
(I ROB) Unit Tll Model-343, PEC 32918, Comcode 406-106-583 at each end.
Terminals J1-3 and J1-6 of the IROB Unit should not be connected. Maximum
distance between a 7300H voice terminal and the system 25 cabinets is 2000
feet. There is no limit on how much of the 2000 feet may be locally powered
using the DS181 522 Kit-of-Parts, Comcode 105-105-514. (Only ZTN79 CP
supports 7300 H-type voice terminals. Secondary wiring protectors are listed in
Table 2-B.)
Off-Premises-DS1 Interface
The TN767 DS1 Interface can support up to 24 analog off-premises stations
through the use of a D4 channel bank.
Make the connections shown in Figure 2-41 at the S25. The CSU can be
powered by the line or from a locally provided -48 V dc power supply. The -48 V
and GRD leads are optional according to how the CSU is powered. For the
connections at the D4, refer to the D4 installation document (555-170-102).
Secondary wiring protectors are listed in Table 2-B.